Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.758
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(50): e2213157119, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36490316

RESUMO

The formation of toxic Amyloid ß-peptide (Aß) oligomers is one of the earliest events in the molecular pathology of Alzheimer's Disease (AD). These oligomers lead to a variety of downstream effects, including impaired neuronal signaling, neuroinflammation, tau phosphorylation, and neurodegeneration, and it is estimated that these events begin 10 to 20 y before the presentation of symptoms. Toxic Aß oligomers contain a nonstandard protein structure, termed α-sheet, and designed α-sheet peptides target this main-chain structure in toxic oligomers independent of sequence. Here we show that a designed α-sheet peptide inhibits the deleterious effects on neuronal signaling and also serves as a capture agent in our soluble oligomer binding assay (SOBA). Pre-incubated synthetic α-sheet-containing Aß oligomers produce strong SOBA signals, while monomeric and ß-sheet protofibrillar Aß do not. α-sheet containing oligomers were also present in cerebrospinal fluid (CSF) from an AD patient versus a noncognitively impaired control. For the detection of toxic oligomers in plasma, we developed a plate coating to increase the density of the capture peptide. The proof of concept was achieved by testing 379 banked human plasma samples. SOBA detected Aß oligomers in patients on the AD continuum, including controls who later progressed to mild cognitive impairment. In addition, SOBA discriminated AD from other forms of dementia, yielding sensitivity and specificity of 99% relative to clinical and neuropathological diagnoses. To explore the broader potential of SOBA, we adapted the assay for a-synuclein oligomers and confirmed their presence in CSF from patients with Parkinson's disease and Lewy body dementia.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/sangue , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/sangue , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Peptídeos beta-Amiloides/metabolismo , Doença de Parkinson/sangue , Doença de Parkinson/líquido cefalorraquidiano , Doença de Parkinson/metabolismo , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/líquido cefalorraquidiano , Fragmentos de Peptídeos/metabolismo , Líquido Cefalorraquidiano/química , Doença por Corpos de Lewy/sangue , Doença por Corpos de Lewy/líquido cefalorraquidiano , Doença por Corpos de Lewy/metabolismo , Técnicas Imunoenzimáticas/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-35805441

RESUMO

The SARS-CoV-2 virus, which is driving the current COVID-19 epidemic, has been detected in wastewater and is being utilized as a surveillance tool to establish an early warning system to aid in the management and prevention of future pandemics. qPCR is the method usually used to detect SARS-CoV-2 in wastewater. There has been no study using an immunoassay that is less laboratory-intensive than qPCR with a shorter turnaround time. Therefore, we aimed to evaluate the performance of an automated chemiluminescence enzyme immunoassay (CLEIA) for SARS-CoV-2 antigen in wastewater. The CLEIA assay achieved 100% sensitivity and 66.7% specificity in a field-captured wastewater sample compared to the gold standard RT-qPCR. Our early findings suggest that the SARS-CoV-2 antigen can be identified in wastewater samples using an automated CLEIA, reducing the turnaround time and improving the performance of SARS-CoV-2 wastewater monitoring during the pandemic.


Assuntos
COVID-19 , Técnicas Imunoenzimáticas , SARS-CoV-2 , Águas Residuárias , Antígenos Virais/imunologia , Antígenos Virais/isolamento & purificação , COVID-19/epidemiologia , COVID-19/prevenção & controle , Humanos , Técnicas Imunoenzimáticas/métodos , Medições Luminescentes , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Águas Residuárias/virologia , Vigilância Epidemiológica Baseada em Águas Residuárias
3.
Dig Dis Sci ; 67(1): 16-25, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34846676

RESUMO

Infectious diarrhea is caused by a variety of pathogens, including viruses, bacteria, and parasitic organisms. Though the causative agent of diarrhea has historically been evaluated via stool cultures, recently, culture-independent diagnostic tests (CIDT) have been developed and utilized with increasing frequency. Current practice guidelines recommend their use as adjuncts to stool cultures for diagnosing acute and chronic diarrhea. The three principal CIDT are microscopy, enzyme-based immunoassays (EIAs), and molecular based polymerase chain reaction (PCR). This review explores the common causes of infectious diarrhea, the basics of stool culture, the diagnostic utility of these three culture-independent modalities, and the strengths and weaknesses of all currently available clinical techniques. It also outlines considerations for specific populations including returning travelers and those with inflammatory bowel disease.


Assuntos
Diarreia , Fezes/microbiologia , Técnicas Imunoenzimáticas/métodos , Técnicas Microbiológicas , Microscopia/métodos , Reação em Cadeia da Polimerase/métodos , Meios de Cultura , Diarreia/diagnóstico , Diarreia/microbiologia , Humanos , Técnicas Microbiológicas/métodos
6.
Toxins (Basel) ; 13(10)2021 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-34678966

RESUMO

Ochratoxins are mycotoxins that have been extensively studied lately due to the multiple toxic effects such as nephrotoxicity, hepatotoxicity, and carcinogenicity. These toxins contaminate plant and animal foods and after ingestion they reach into body fluids. The method of competitive direct enzyme immunoassay, in the solid phase, was validated through the determination of specific parameters (performance, linearity, recovery percentage, limit of detection, limit of quantification). The validated method was used to determine ochratoxin A in colostrum and cow's milk. The method applied for the determination of ochratoxin A was linear for the concentration range of 0.0-0.5 ng/mL, the value for the regression coefficient (r) was 0.9838. Ochratoxin A was present in 91.67% of the colostrum and in 93.33% of cow's milk samples. The linearity of the method, demonstrated for very low concentrations of analyte, the detection limit as well as the limit of quantification recommend the method for the determinations of micro-pollutants from foods, including biological fluids.


Assuntos
Colostro/química , Leite/química , Ocratoxinas/análise , Animais , Bovinos , Feminino , Contaminação de Alimentos/análise , Humanos , Técnicas Imunoenzimáticas/métodos , Gravidez , Romênia
7.
Microbiol Spectr ; 9(2): e0079921, 2021 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-34668727

RESUMO

The importance of the detection of relevant toxins or toxin genes to diagnose Clostridioides difficile infection (CDI) or the prediction of clinical outcomes of CDI has been emphasized in recent years. Although stool culture of C. difficile is not routinely recommended in the era of nonculture methods as the preferred tools for CDI diagnosis, the clinical significance of toxigenic C. difficile growth (tCdG) in stool cultures was analyzed. A clinical study was conducted in medical wards of Tainan Hospital, Ministry of Health and Welfare, in southern Taiwan. Diarrheal adults with fecal glutamate dehydrogenase and C. difficile toxin between January 2013 and April 2020 were included. Of the 209 patients with CDI, 158 (75.6%) had tCdG found in stool cultures, and the rest (51, 24.4%) had no tCdG in stool. Only prior ceftazidime or ceftriaxone therapy was independently associated with no tCdG in stool (odds ratio [OR] 2.17, P = 0.02). Compared to the patients with tCDG in stool, those without tCdG in stool experienced treatment success more often (97.1% versus 67.0%, P < 0.001) if treated with metronidazole or vancomycin but had a similar in-hospital mortality or recurrence rate. In the multivariate analysis among 114 patients with CDI treated with metronidazole or vancomycin, treatment success was independently associated with no tCdG in stool (OR 12.7, P = 0.02). Despite the limited utility of stool cultures in CDI diagnoses, no tCdG in stool culture heralds a favorable therapeutic outcome among adults with CDI treated with metronidazole or vancomycin. IMPORTANCE The importance of detecting toxins or toxin genes when diagnosing Clostridioides difficile infections (CDIs) or predicting the severity and outcomes of CDI has been emphasized in recent years. Although the yielding of C. difficile from stool cultures might implicate higher bacterial loads in fecal samples, in an era of nonculture methods for the standard diagnosis of CDIs, clinical significance of positive stool cultures of toxigenic C. difficile was analyzed in this study. Despite the limited ability of stool cultures in CDI diagnoses, no yielding of C. difficile growth might predict the successful CDI therapy.


Assuntos
Clostridioides difficile/isolamento & purificação , Clostridioides/isolamento & purificação , Infecções por Clostridium/diagnóstico , Testes Diagnósticos de Rotina/métodos , Fezes/microbiologia , Idoso , Idoso de 80 Anos ou mais , Técnicas Bacteriológicas/métodos , Infecções por Clostridium/tratamento farmacológico , Diarreia/diagnóstico , Diarreia/tratamento farmacológico , Diarreia/microbiologia , Feminino , Humanos , Técnicas Imunoenzimáticas/métodos , Masculino , Metronidazol/uso terapêutico , Pessoa de Meia-Idade , Análise Multivariada , Resultado do Tratamento , Vancomicina/uso terapêutico
8.
Sci Rep ; 11(1): 18187, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34521905

RESUMO

Fragmented cytokeratin 18 (fCK18) released from epithelial cells undergoing apoptosis is widely studied in various diseases. However, fCK18 measurement is not utilized in clinical practice due to imprecise disease-state cutoff values. Therefore, we set out to generate new monoclonal antibodies (mAbs) and a recombinant fCK18 (rfCK18) calibrator in an effort to develop a highly sensitive chemiluminescent enzyme immunoassay (CLEIA). New capture mAb (K18-624) had a high binding ability compared to the current commercial antibody. New detection mAb (K18-328) recognized 323S-340G of CK18. A rfCK18 was expressed in the soluble fraction of E. coli when the N-terminal region (260 amino acid residues) of CK18 was truncated. Analysis of performance and measurement of human fCK18 were evaluated using K18-624 and K18-328 in a highly sensitive CLEIA. The coefficients of variation (CV) for within-run and between-day repeatability were below 10% and the recoveries were in the range of 15%. The detection sensitivity was 0.056 ng/mL. Serum fCK18 levels were significantly increased in non-alcoholic steatohepatitis (NASH) patients when compared to healthy individuals. Our new fCK18 mAbs showed high affinity and sensitivity. CLEIA using our new antibodies will be useful in measuring fCK18 in human blood thereby generating accurate clinical diagnoses of human liver diseases.


Assuntos
Anticorpos Monoclonais/imunologia , Queratina-18/sangue , Técnicas de Diagnóstico Molecular/métodos , Hepatopatia Gordurosa não Alcoólica/sangue , Biomarcadores/sangue , Humanos , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Queratina-18/imunologia , Técnicas de Diagnóstico Molecular/normas , Sensibilidade e Especificidade
9.
Biochem Biophys Res Commun ; 576: 22-26, 2021 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-34478915

RESUMO

Blood based ß-amyloid (Aß) assays that can predict amyloid positivity in the brain are in high demand. Current studies that utilize immunoprecipitation mass spectrometry assay (IP-MS), which has high specificity for measuring analytes, have revealed that precise plasma Aß assays have the potential to detect amyloid positivity in the brain. In this study, we developed plasma Aß40 and Aß42 immunoassays using a fully automated immunoassay platform that is used in routine clinical practice. Our assays showed high sensitivity (limit of quantification: 2.46 pg/mL [Aß40] and 0.16 pg/mL [Aß42]) and high reproducibility within-run (coefficients of variation [CVs]: <3.7% [Aß40] and <2.0% [Aß42]) and within-laboratory (CVs: <4.6% [Aß40] and <5.3% [Aß42]). The interference from plasma components was less than 10%, and the cross-reactivity with various lengths of Aß peptides was less than 0.5%. In addition, we found a significant correlation between the IP-MS method and our immunoassay (correlation coefficients of Pearson's r: 0.91 [Aß40] and 0.82 [Aß42]). Our new method to quantify plasma Aß40 and Aß42 provides clinicians and patients with a way to continuously monitor disease progression.


Assuntos
Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides/sangue , Técnicas Imunoenzimáticas/métodos , Imunoprecipitação/métodos , Espectrometria de Massas/métodos , Fragmentos de Peptídeos/sangue , Plasma/metabolismo , Doença de Alzheimer/sangue , Biomarcadores/sangue , Humanos , Luminescência , Reprodutibilidade dos Testes
10.
Int J Mol Sci ; 22(16)2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34445351

RESUMO

Multiplexed single-cell analysis of proteins in their native cellular contexts holds great promise to reveal the composition, interaction and function of the distinct cell types in complex biological systems. However, the existing multiplexed protein imaging technologies are limited by their detection sensitivity or technical demands. To address these issues, here, we develop an ultrasensitive and multiplexed in situ protein profiling approach by reiterative staining with off-the-shelf antibodies and cleavable fluorescent tyramide (CFT). In each cycle of this approach, the protein targets are recognized by antibodies labeled with horseradish peroxidase, which catalyze the covalent deposition of CFT on or close to the protein targets. After imaging, the fluorophores are chemically cleaved, and the antibodies are stripped. Through continuous cycles of staining, imaging, fluorophore cleavage and antibody stripping, a large number of proteins can be quantified in individual cells in situ. Applying this method, we analyzed 20 different proteins in each of ~67,000 cells in a human formalin-fixed paraffin-embedded (FFPE) tonsil tissue. Based on their unique protein expression profiles and microenvironment, these individual cells are partitioned into different cell clusters. We also explored the cell-cell interactions in the tissue by examining which specific cell clusters are selectively associating or avoiding each other.


Assuntos
Diagnóstico por Imagem/métodos , Proteínas/metabolismo , Análise de Célula Única/métodos , Anticorpos/metabolismo , Comunicação Celular , Imunofluorescência/métodos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Formaldeído/química , Peroxidase do Rábano Silvestre/análise , Peroxidase do Rábano Silvestre/metabolismo , Humanos , Técnicas Imunoenzimáticas/métodos , Tonsila Palatina/química , Tonsila Palatina/citologia , Tonsila Palatina/metabolismo , Inclusão em Parafina , Proteínas/análise , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos
11.
J Clin Lab Anal ; 35(9): e23914, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34347308

RESUMO

BACKGROUND: The diagnosis of systemic autoimmune rheumatic diseases (SARD) is based on the detection of serum antinuclear antibodies (ANA) for which indirect immunofluorescence (IIF) is the golden standard. New solid-phase immunoassays have been developed to be used alone or in combination with the detection of extractable antinuclear antibodies (ENA) to improve SARD diagnosis. The purpose of this study was to compare the clinical performances of different ANA screening methods alone or in combination with ENA screening methods for SARD diagnosis. METHODS: A total of 323 patients were screened for ANA by IIF, EliA™ CTD Screen, and ELISA methods. Agreements were calculated between the methods. Then, EliA™ CTD Screen positive samples were screened for ENA by line immunoassay (LIA) and fluorescence enzyme immunoassay (FEIA). RESULTS: The diagnostic accuracy of EliA™ CTD Screen (79% sensitivity and 91% specificity) was better than that of ELISA or IIF. The combination of EliA™ CTD plus IIF had the highest sensitivity (93%). ENA determination revealed that Ro52 and Ro60 were the most prevalent specificities. The use of IIF alone was not able of detecting up to 36% of samples positive for Ro52, and 41% for Ro60. CONCLUSIONS: EliA™ CTD Screen has a better diagnostic performance when compared to IIF and ELISA. The combined use of EliA™ CTD Screen and IIF clearly improves the rate and accuracy of SARD diagnosis. The use of EliA™ CTD Screen as first-line screening technique allows the detection of antibodies, which could not be detected by IIF alone.


Assuntos
Anticorpos Antinucleares/sangue , Doenças Autoimunes/diagnóstico , Programas de Rastreamento/métodos , Doenças Reumáticas/diagnóstico , Anticorpos Antinucleares/imunologia , Doenças Autoimunes/sangue , Doenças Autoimunes/imunologia , Testes de Coagulação Sanguínea/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Técnica Indireta de Fluorescência para Anticorpo/métodos , Humanos , Imunoensaio/métodos , Técnicas Imunoenzimáticas/métodos , Masculino , Pessoa de Meia-Idade , Doenças Reumáticas/sangue , Doenças Reumáticas/imunologia
12.
Diagn Microbiol Infect Dis ; 101(3): 115489, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34352435

RESUMO

BACKGROUND: Parvovirus B19 is a pathogenic virus often diagnosed by serology, yet little is known about analytical performance of commercial enzyme immunoassays (EIAs). OBJECTIVE: To investigate performance of 4 EIAs for parvovirus B19 IgM and IgG: Liaison, Euroimmun, Mikrogen and Virion/Serion. STUDY DESIGN: To compare 4 EIAs to Biotrin's ELISA on 168 samples and determine consensus score for discordant samples using Mikrogen's confirmatory line assay. RESULTS: Two thirds of results for IgM/IgG were identical for all 4 EIAs and Biotrin. Liaison shows the highest IgM sensitivity, but has low specificity. Euroimmun lacks IgM sensitivity. Mikrogen had a good overall performance, but had the lowest IgG specificity. Virion/Serion had variable performance with a low IgM specificity and the most borderline and cross-reactive results. CONCLUSIONS: Liaison and Mikrogen have similar performance to Biotrin's ELISA. Euroimmun lacks sensitivity and Virion/Serion produced many borderline and cross-reactive results.


Assuntos
Anticorpos Antivirais/sangue , Eritema Infeccioso/diagnóstico , Técnicas Imunoenzimáticas/normas , Parvovirus B19 Humano/imunologia , Testes Sorológicos/normas , Eritema Infeccioso/imunologia , Humanos , Técnicas Imunoenzimáticas/métodos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Sensibilidade e Especificidade , Testes Sorológicos/métodos
13.
Int J Lab Hematol ; 43(6): 1593-1598, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34252265

RESUMO

BACKGROUND: The Sysmex CN-6500 is a new haemostasis analyser with an integrated immunoassay module that performs chemiluminescence enzyme assay (CLEIA) in addition to coagulation, turbidimetric, chromogenic and platelet aggregation tests. AIMS: To evaluate the analytical performance of the CN-6500 against the predicate device (Sysmex HISCL-800) for soluble thrombomodulin (TM), thrombin-antithrombin (TAT), tissue plasminogen activator/plasminogen activator inhibitor 1 complex (tPAI-C) and plasmin α2 plasmin inhibitor complex (PIC) assays. METHODS: Imprecision was assessed by testing two levels of quality control plasmas 10 times on 5 separate days. Comparability was studied in 230 plasmas from normal donors (n = 30), patients with suspected disseminated intravascular coagulation (DIC, n = 100), sepsis (n = 20) or liver disease (n = 20), lipaemic (n = 20), haemolysed (n = 20) and icteric samples (n = 20). Limit of detection, limit of quantitation and linearity were determined by testing serial dilutions of normal plasma. Sample carryover was assessed by testing samples with high and low normal levels of the analytes concerned. RESULTS: The CN-6500 performed 21 CLEIA tests per hour, while simultaneously performing coagulation tests. Acceptable between-run imprecision was obtained using commercial controls with normal and high activity for each analyte (%CV <4%), for all four assays. Excellent linearity was observed (slope 0.89-1.03; r2 >0.99) across the measurement range. The lower limits of detection and quantitation were as follows: TM <0.3/0.6 TU/ml, TAT >0.1/<0.2 ng/ml, PIC <0.004/<0.008 µg/ml and tPAI-C < 0.01/<0.1 ng/ml, respectively. All four assays showed excellent correlation between analysers and were unaffected by haemolysis, icterus or lipaemia. No carryover was observed. CONCLUSIONS: Our data demonstrate that the performance of the CLEIA assays on the CN-6500 is comparable to that of a stand-alone immunoassay analyser.


Assuntos
Testes de Coagulação Sanguínea/normas , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Medições Luminescentes/métodos , Medições Luminescentes/normas , Automação Laboratorial , Coagulação Sanguínea , Testes de Coagulação Sanguínea/instrumentação , Testes de Coagulação Sanguínea/métodos , Humanos , Técnicas Imunoenzimáticas/instrumentação , Medições Luminescentes/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Acquir Immune Defic Syndr ; 87(4): 1072-1078, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34153013

RESUMO

BACKGROUND: Virological failure during antiretroviral treatment (ART) may indicate the presence of drug resistance, but may also originate from nonadherence. Qualitative detection of ART components using drug level testing may be used to differentiate between these scenarios. We aimed to validate and implement qualitative point-of-care drug level tests for efavirenz (EFV), lopinavir (LPV), and dolutegravir (DTG) in rural South Africa. METHODS: Qualitative performance of immunoassays for EFV, LPV, and DTG was assessed by calculating limit of detection (LoD), region of uncertainty, and qualitative agreement with a reference test. Minimum duration of nonadherence resulting in a negative drug level test was assessed by simulation of treatment cessation using validated population pharmacokinetic models. RESULTS: LoD was 0.05 mg/L for EFV, 0.06 mg/L for LPV, and 0.02 mg/L for DTG. Region of uncertainty was 0.01-0.06 mg/L for EFV, 0.01-0.07 mg/L for LPV, and 0.01-0.02 mg/L for DTG. Qualitative agreement with reference testing at the LoD in patient samples was 95.2% (79/83) for EFV, 99.3% (140/141) for LPV, and 100% (118/118) for DTG. After simulated treatment cessation, median time to undetectability below LoD was 7 days [interquartile range (IQR) 4-13] for EFV, 30 hours (IQR 24-36) for LPV, and 6 days (IQR 4-7) for DTG. CONCLUSIONS: We demonstrate that qualitative ART drug level testing using immunoassays is feasible in a rural resource-limited setting. Implementation of this technology enables reliable detection of recent nonadherence and may allow for rapid and cost-effective differentiation between patients in need for adherence counseling and patients who require drug resistance testing or alternative treatment.


Assuntos
Alcinos/administração & dosagem , Fármacos Anti-HIV/sangue , Benzoxazinas/administração & dosagem , Ciclopropanos/administração & dosagem , Compostos Heterocíclicos com 3 Anéis/administração & dosagem , Lopinavir/administração & dosagem , Adesão à Medicação , Oxazinas/administração & dosagem , Piperazinas/administração & dosagem , Testes Imediatos/normas , Piridonas/administração & dosagem , Alcinos/farmacocinética , Alcinos/uso terapêutico , Fármacos Anti-HIV/administração & dosagem , Benzoxazinas/farmacocinética , Benzoxazinas/uso terapêutico , Ciclopropanos/farmacocinética , Ciclopropanos/uso terapêutico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/metabolismo , HIV-1 , Compostos Heterocíclicos com 3 Anéis/farmacocinética , Compostos Heterocíclicos com 3 Anéis/uso terapêutico , Humanos , Técnicas Imunoenzimáticas/métodos , Limite de Detecção , Lopinavir/farmacocinética , Lopinavir/uso terapêutico , Oxazinas/farmacocinética , Oxazinas/uso terapêutico , Piperazinas/farmacocinética , Piperazinas/uso terapêutico , Testes Imediatos/economia , Piridonas/farmacocinética , Piridonas/uso terapêutico , Reprodutibilidade dos Testes , População Rural , África do Sul
15.
Rev Bras Ginecol Obstet ; 43(5): 351-356, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34077987

RESUMO

OBJECTIVE: Most prenatal screening programs for toxoplasmosis use immunoassays in serum samples of pregnant women. Few studies assess the accuracy of screening tests in dried blood spots, which are of easy collection, storage, and transportation. The goals of the present study are to determine the performance and evaluate the agreement between an immunoassay of dried blood spots and a reference test in the serum of pregnant women from a population-based prenatal screening program for toxoplasmosis in Brazil. METHODS: A cross-sectional study was performed to compare the immunoassays Imunoscreen Toxoplasmose IgM and Imunoscreen Toxoplasmose IgG (Mbiolog Diagnósticos, Ltda., Contagem, Minas Gerais, Brazil)in dried blood spots with the enzyme-linked fluorescent assay (ELFA, BioMérieux S.A., Lyon, France) reference standard in the serum of pregnant women from Minas Gerais Congenital Toxoplasmosis Control Program. RESULTS: The dried blood spot test was able to discriminate positive and negative results of pregnant women when compared with the reference test, with an accuracy of 98.2% for immunoglobulin G (IgG), and of 95.8% for immunoglobulin M (IgM). CONCLUSION: Dried blood samples are easy to collect, store, and transport, and they have a good performance, making this a promising method for prenatal toxoplasmosis screening programs in countries with continental dimensions, limited resources, and a high prevalence of toxoplasmosis, as is the case of Brazil.


OBJETIVO: A maioria dos programas de triagem pré-natal para toxoplasmose utiliza imunoensaios em amostras de soro de gestantes. Poucos estudos avaliam a acurácia dos testes de triagem em amostras de sangue seco, que são de fácil coleta, armazenamento e transporte. Este estudo teve como objetivo determinar o desempenho e avaliar a concordância entre um imunoensaio em sangue seco e um teste de referência em soro de gestantes de um programa de rastreamento pré-natal de base populacional para toxoplasmose no Brasil. MéTODOS: Realizou-se um estudo transversal para comparar os imunoensaios Imunoscreen Toxoplasmose IgM e Imunoscreen Toxoplasmose IgG (Mbiolog Diagnósticos, Ltda., Contagem, Minas Gerais, Brazil) em sangue seco com o padrão de referência ensaio fluorescente ligado a enzimas (enzyme-linked fluorescent assay, ELFA, BioMérieux S.A., Lion, França) no soro de gestantes do Programa de Controle de Toxoplasmose Congênita de Minas Gerais. RESULTADOS: O exame em sangue seco foi capaz de discriminar os resultados positivos e negativos das gestantes quando comparado ao teste de referência, com acurácia de 98,2% para imunoglobulina G (IgG), e de 95,8% para imunoglobulina M (IgM). CONCLUSãO: O sangue seco apresenta bom desempenho e é uma amostra de fácil coleta, armazenamento e transporte, o que o torna um método promissor para programas de triagem pré-natal de toxoplasmose em países com dimensões continentais, recursos limitados, e alta prevalência de toxoplasmose, como é o caso do Brasil.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Técnicas Imunoenzimáticas/métodos , Toxoplasma/isolamento & purificação , Toxoplasmose Congênita/diagnóstico , Toxoplasmose/diagnóstico , Anticorpos Antiprotozoários/sangue , Brasil/epidemiologia , Estudos Transversais , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Programas de Rastreamento , Vigilância da População , Gravidez , Gestantes , Diagnóstico Pré-Natal , Prevalência , Toxoplasma/imunologia , Toxoplasmose/epidemiologia , Toxoplasmose Congênita/epidemiologia
16.
J Med Virol ; 93(12): 6778-6781, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34170555

RESUMO

A high-throughput, fully automated antigen detection test for SARS-CoV-2 is a viable alternative to reverse-transcription polymerase chain reaction (RT-qPCR) for mass screening during outbreaks. In this study, we compared RT-qPCR for viral load and the VITROS® SARS-CoV-2 Antigen Test with reference to the results of the LUMIPULSE® SARS-CoV-2 Ag Test. Of 128 nasopharyngeal swab specimens taken from patients suspected of being infected with SARS-CoV-2, 49 were positive and 79 were negative according to RT-qPCR. Consistent dose-dependent detection with VITROS® assay was successfully achieved when using nasopharyngeal swab specimens with Ct values of 32.0 or lesser, whereas the CLEIA-based LUMIPULSE® assay was able to detect lower viral loads compared with the VITROS® assay. Our results show that the performance of the VITROS® assay was satisfactory for the diagnosis of contagious COVID-19 patients in the clinical setting. Highlights The performance of the VITROS® SARS-CoV-2 Antigen Test was sufficient for the diagnosis of contagious COVID-19. This test showed high sensitivity and specificity in the detection of SARS-CoV-2 in samples with a Ct value of 32 or less.


Assuntos
Teste Sorológico para COVID-19/métodos , Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Técnicas Imunoenzimáticas/métodos , Testes Imunológicos/métodos , SARS-CoV-2/imunologia , Antígenos Virais/genética , Antígenos Virais/imunologia , COVID-19/virologia , Humanos , Programas de Rastreamento/métodos , Nasofaringe/imunologia , Nasofaringe/virologia , RNA Viral/genética , RNA Viral/imunologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , Sensibilidade e Especificidade , Carga Viral/genética , Carga Viral/imunologia
17.
Transfusion ; 61(8): 2240-2244, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34056747

RESUMO

BACKGROUND: Human parvovirus B19 (B19) is a pathogen that threatens the quality of plasma products. Therefore, health authorities have mandated measures against B19 contamination of plasma pools. The US FDA has recommended a B19 genome level of 104 IU/ml or lower in pooled plasma lots. Therefore, the B19 nucleic acid amplification test (B19-NAT) has been introduced in many plasma fractionators. However, in the Japanese Red Cross, which is the only approved blood collector in Japan, the B19 antigen test has been introduced for screening donated blood in Japan. Therefore, to clarify whether the antigen test is robust enough to screen blood samples according to the FDA recommendation, we evaluated B19 genome levels in each pooled plasma lot from 2003 to 2020. STUDY DESIGN AND METHODS: Data of 5576 pooled plasma lots from factories A and B, which were derived from plasma bags and passed the B19 antigen-based tests, receptor-mediated hemagglutination assay (B19-RHA), or chemiluminescent enzyme immunoassay (B19-CLEIA), during 2003 to 2020, were evaluated. The amount of B19 genome in each lot was determined using quantitative or semiquantitative B19-NAT. RESULTS: The B19 genome levels in pooled plasma lots screened using B19-RHA did not meet the FDA recommendation, whereas the lots derived from B19-CLEIA fulfilled the FDA recommendation, even during the B19 epidemic in Japan. DISCUSSION: The results suggest that the B19-CLEIA donor screening for plasma pools is also useful in light of the US FDA recommendation.


Assuntos
Antígenos Virais/análise , DNA Viral/análise , Infecções por Parvoviridae/diagnóstico , Parvovirus B19 Humano/isolamento & purificação , Antígenos Virais/sangue , DNA Viral/sangue , Humanos , Técnicas Imunoenzimáticas/métodos , Programas de Rastreamento , Técnicas de Amplificação de Ácido Nucleico/métodos , Infecções por Parvoviridae/sangue , Infecções por Parvoviridae/virologia
18.
J Immunol Res ; 2021: 5591115, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33997056

RESUMO

Tetranor-PGDM is a metabolite of PGD2. Urinary tetranor-PGDM levels were reported to be increased in some diseases, including food allergy, Duchenne muscular dystrophy, and aspirin-intolerant asthma. In this study, we developed a monoclonal antibody (MAb) and a competitive enzyme immunoassay (EIA) for measuring tetranor-PGDM. Spleen cells isolated from mice immunized with tetranor-PGDM were utilized to generate Ab-producing hybridomas. We chose hybridomas and purified MAb against tetranor-PGDM to develop competitive EIA. The assay evaluated the optimal ionic strength, pH, precision, and reliability. Specificity was determined by cross-reactivity to tetranor-PGEM, tetranor-PGFM, and tetranor-PGAM. Recovery was determined by spiking experiments on artificial urine. Optimal ionic strength was 150 mM NaCl, and optimal pH was pH 7.5. Metabolites other than tetranor-PGDM did not show any significant cross-reactivity in the EIA. The assay exhibited a half-maximal inhibition concentration (IC50) of 1.79 ng/mL, limit of detection (LOD) of 0.0498 ng/mL, and range of quantitation (ROQ) value of 0.252 to 20.2 ng/mL. The intra- and inter-assay variation for tetranor-PGDM was 3.9-6.0% and 5.7-10.4%, respectively. The linearity-dilution effect showed excellent linearity under dilution when artificial urine samples were applied to solid-phase extraction (SPE). After SPE, recovery of tetranor-PGDM in artificial urine averaged from 82.3% to 113.5% and was within acceptable limits (80%-120%). We successfully generated one monoclonal antibody and developed a sensitive competitive EIA. The established EIA would be useful for routine detection and monitoring of tetranor-PGDM in research or diagnostic body fluids.


Assuntos
Anticorpos Monoclonais/imunologia , Técnicas Imunoenzimáticas/métodos , Prostaglandina D2/análogos & derivados , Animais , Anticorpos Monoclonais/isolamento & purificação , Feminino , Camundongos , Modelos Animais , Prostaglandina D2/imunologia , Prostaglandina D2/metabolismo , Prostaglandina D2/urina , Reprodutibilidade dos Testes
19.
Rev. bras. ginecol. obstet ; 43(5): 351-356, May 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1288563

RESUMO

Abstract Objective Most prenatal screening programs for toxoplasmosis use immunoassays in serum samples of pregnant women. Few studies assess the accuracy of screening tests in dried blood spots, which are of easy collection, storage, and transportation. The goals of the present study are to determine the performance and evaluate the agreement between an immunoassay of dried blood spots and a reference test in the serum of pregnant women from a population-based prenatal screening program for toxoplasmosis in Brazil. Methods A cross-sectional study was performed to compare the immunoassays Imunoscreen Toxoplasmose IgM and Imunoscreen Toxoplasmose IgG (Mbiolog Diagnósticos, Ltda., Contagem, Minas Gerais, Brazil)in dried blood spots with the enzymelinked fluorescent assay (ELFA, BioMérieux S.A., Lyon, France) reference standard in the serum of pregnant women from Minas Gerais Congenital Toxoplasmosis Control Program. Results The dried blood spot test was able to discriminate positive and negative results of pregnant women when comparedwith the reference test, with an accuracy of 98.2% for immunoglobulin G (IgG), and of 95.8% for immunoglobulin M (IgM). Conclusion Dried blood samples are easy to collect, store, and transport, and they have a good performance,making this a promisingmethod for prenatal toxoplasmosis screening programs in countries with continental dimensions, limited resources, and a high prevalence of toxoplasmosis, as is the case of Brazil.


Resumo Objetivo A maioria dos programas de triagem pré-natal para toxoplasmose utiliza imunoensaios em amostras de soro de gestantes. Poucos estudos avaliam a acurácia dos testes de triagem em amostras de sangue seco, que são de fácil coleta, armazenamento e transporte. Este estudo teve como objetivo determinar o desempenho e avaliar a concordância entre um imunoensaio em sangue seco e um teste de referência em soro de gestantes de um programa de rastreamento pré-natal de base populacional para toxoplasmose no Brasil. Métodos Realizou-se um estudo transversal para comparar os imunoensaios Imunoscreen Toxoplasmose IgM e Imunoscreen Toxoplasmose IgG (Mbiolog Diagnósticos, Ltda., Contagem, Minas Gerais, Brazil) em sangue seco com o padrão de referência ensaio fluorescente ligado a enzimas (enzyme-linked fluorescent assay, ELFA, BioMérieux S.A., Lion, França) no soro de gestantes do Programa de Controle de Toxoplasmose Congênita de Minas Gerais. Resultados O exame em sangue seco foi capaz de discriminar os resultados positivos e negativos das gestantes quando comparado ao teste de referência, com acurácia de 98,2% para imunoglobulina G (IgG), e de 95,8% para imunoglobulina M (IgM). Conclusão O sangue seco apresenta bom desempenho e é uma amostra de fácil coleta, armazenamento e transporte, o que o torna um método promissor para programas de triagem pré-natal de toxoplasmose em países com dimensões continentais, recursos limitados, e alta prevalência de toxoplasmose, como é o caso do Brasil.


Assuntos
Humanos , Feminino , Gravidez , Toxoplasma/isolamento & purificação , Toxoplasmose/diagnóstico , Toxoplasmose Congênita/diagnóstico , Técnicas Imunoenzimáticas/métodos , Teste em Amostras de Sangue Seco/métodos , Diagnóstico Pré-Natal , Toxoplasma/imunologia , Brasil/epidemiologia , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Anticorpos Antiprotozoários/sangue , Toxoplasmose/epidemiologia , Toxoplasmose Congênita/epidemiologia , Programas de Rastreamento , Vigilância da População , Prevalência , Estudos Transversais , Gestantes
20.
J Microbiol Methods ; 185: 106226, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33878445

RESUMO

Acute disseminated histoplasmosis (ADH) is an AIDS-defining illness and reported in Cameroon, but there are few data about its incidence. Between June and August 2019, we conducted a descriptive cross-sectional study to screen for histoplasmosis in a population of adults with HIV infection, irrespective of their CD4 T-cell counts, using Histoplasma urine antigen detection enzyme immunoassay (EIA) and histoplasmin skin test. Of the 138 participants screened, 36 (26%) had detectable antigen in urine, using an OD cut off of 0.045. Skin lesions were present in two (6%) cases. Of 39 patients tested for histoplasmin skin test positivity, one was positive. Histoplasma antigenuria was associated with a positive history of chest infection (Odds ratio: 3.632, 95% confidence interval: 1.635-8.071, p= 0.001). As 30 (21.7%) of titres were between 0.045 (the current cut off) and 0.25, the cut off may need adjustment in Cameroon, using disease confirmation with alternative, highly sensitive diagnostic approaches such as PCR and bone marrow examination. H. capsulatum infection appears to be common among HIV-infected patients attending outpatient clinics at the Buea Regional Hospital. There is an acute need to improve awareness and management of HIV patients with respect to H. capsulatum infection.


Assuntos
Infecções por HIV/complicações , Histoplasmose/diagnóstico , Técnicas Imunoenzimáticas/métodos , Programas de Rastreamento/métodos , Adulto , Antígenos de Fungos/urina , Contagem de Linfócito CD4 , Camarões , Estudos Transversais , Feminino , Histoplasma , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reação em Cadeia da Polimerase , Carga Viral , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...